Remote batch controller for panel or
wall mounting for connection to Bürkert
8020/8030/8031/8041/8071 flowmeter
burkert8025流量有货426872 426874 418778 418672 418779 423913

打印当前页

发邮件给我们:514403665@qq.com

分享到:
在线咨询 点击收藏

burkert8025流量有货426872 426874 418778 418672 418779 423913

8025 Batch controller INSERTION p. 2/12 Operation and display (common to the various versions) When mounted in a pipe (compact version) or connected to a flowmeter (remote version) in series with one or two valves, the 8025 batch controller makes it possible to carry out a dosing of one or several quantities of liquids. The unit controls the opening of the valves and measures the quantity of the fluid which flows. The unit also closes the valves when the preset quantity has been delivered. The electronic component needs a voltage supply of 12...36 V DC or 115/230 V AC. The device is equipped with 4 digital inputs (DI1 up to DI4), 2 transistor outputs (DO1 configured as a pulse output and DO4 configured as state output, by default), 2 relay outputs (DO2 always configured to control the valve and by default parameterize of * of the batch quantity and DO3 configured as alarm output by default), two volume or mass totalizers and two batch totalizers. The second relay output can be used to activate another valve, to initiate alarms or to generate warnings. The following dosing modes are possible: - Locally started dosing of free quantity: the user enters the quantity to be filled and starts the dosing from the keypad. - Locally started dosing of preset quantity: the user selects a quantity which has been preset and starts the dosing from the keypad. - Locally started dosing of free/preset quantity the user enters the quantity to be filled or selects a quantity which has been preset and starts the dosing from the keypad. - Dosing controlled by a PLC unit the user selects a quantity which has been preset and starts the dosing using binary inputs. - Locally/remote selection of preset quantity and dosing controlled by a PLC unit: the user selects a quantity which has been preset from the keypad or using binary inputs and starts the dosing using binary inputs. - Automatic dosing controlled by variation of pulse duration: the quantity of the dosing is directly proportional to the duration of a pulse. - Remote dosing determined by Teach-In: Teach-In of the dosing quantity using binary inputs. - Local dosing determined by Teach-In: Teach-In of the dosing quantity from the keypad

burkert8025流量有货426872 426874 418778 418672 418779 423913

8025 Batch controller INSERTION COMPACT p. 4/12 The compact batch controller The compact batch controller combines a paddle-wheel flow sensor and an electronic module with a display in an IP65 enclosure. The electrical connection is provided via two cable glands. Bürkert designed fitting S020 ensures simple installation of the Bürkert sensor into pipes from DN20 to DN400. Principle of operation When liquid flows through the pipe, the 4 magnets, inserted in the paddle-wheel set in rotation, produce a measuring signal in the transducer (Hall sensor). The frequency modulated induced voltage is proportional to the flow velocity of the fluid. A conversion coefficient (K-factor, available in the instruction manual of the S020 fitting), specific to each pipe (size and material) enables the conversion of this frequency into a volume or a mass. The electronic component converts the measured signal and displays the actual value of the volume or mass. Technical data General data Compatibility with fittings S020 (see corresponding data sheet) Materials Housing, cover, lid, nut Front panel foil / Screws Cable glands Wetted parts materials Fitting Sensor holder, paddle-wheel Axis and bearing / Seal PC Polyester / Stainless steel PA Brass, stainless steel 1.4404/316L, PVC, PP or PVDF PVDF Ceramics / FKM (EPDM option) Electrical connections Cable glands M20 x 1.5 Device data (Fitting S020 + batch controller) Pipe diameter DN20...DN400 Measuring range 0.3...10 m/s (Hall transducer version) Fluid temperature with fitting in PVC / PP PVDF, brass or stainless steel 0...+50°C (+32...+122°F) / 0...+80°C (+32...+176°F) -15...+80°C (+5...+176°F) Fluid pressure max. PN10 (145.1 PSI) (see pressure/temperature diagram on page 5) Viscosity / Pollution 300 cSt. max. / 1% max. Measurement deviation Teach-In Standard K-factor ±1% of Reading1) (at the teach flow rate value) ±2.5% of Reading1) Linearity ±0.5% of F.S.1) Repeatability ±0.4% of Reading1) Electrical data Power supply (V+) 12...36 V DC (max tolerance: -5% or +10% at 12 V DC; ±10% at 36 V DC), filtered and regulated, SELV (safety extra low voltage), circuit with a non dangerous energy level or 115/230 V AC 50/60 Hz (see technical specifications 115/230 V AC) Reversed polarity of DC protected Current consumption with sensor (without consumption of digital input and pulse output) with relays  90 mA at 12 V DC;  45 mA at 36 V DC Inputs DI (1 to 4) Switching threshold Von: 5...36 V DC; Switching threshold Voff max: 2 V DC; Input impedance: 9.4 KOhms; Galvanic insulation, protected against polarity reversals and voltage spike Outputs Transistors (DO1 and DO4) Relays (DO2 and DO3) NPN or PNP (wiring dependent), potential free; function: pulse output (by default for DO1), batch state (by default for DO4), configurable and parameterizable 0.6...2200 Hz, 5...36 V DC, 100 mA max., line drop 2.7 V DC at 100 mA duty cycle: > 0.45 if 0.6 < frequency < 300 Hz > 0.4 if 300 < frequency < 1500 Hz < 0.4 if 1500 < frequency < 2200 Hz Galvanic insulation, protected against overvoltage, polarity reversals and short-circuits 2 relays (normally open), parameterizable (by default: DO2 always configured to control the valve, parameterized of * of the batch quantity and DO3 configured as alarm), 230 V AC/3 A or 40 V DC/3 A (resistive load), max. cutting power of 750 VA (resistive load) Environment Ambient temperature (operation and storage) -10...+60°C (+14...+140°F) (version 12...36 V DC) -10...+50°C (+14...+122°F) (version 115/230 V AC) * F.S.=Full scale (10 m/s) 1) Under reference conditions i.e. measuring fluid = water, ambient and water temperature = 20°C (68°F), applying the minimum inlet and outlet pipe straights, matched inside pipe dimensions

 

423913

 

联系方式
  • 电话

    18601768506

在线客服